vshmidt
/
masstransit
Обзор
Документация
Войти
/
vshmidt
/
masstransit
Код
Запросы
0
Задачи
Вики
Пакеты
0
Релизы
0
Аналитика
Безопасность
develop
src/MassTransit/Configuration/KillSwitchConfigurationExtensions.cs
98 строк
4 KB
Chris Patterson
Fixed #3966 - changed kill switch configuration so that it should properly monitor activity pass/fail.
22 дек 2022, 19:07
22 дек 2022, 19:07
6568255
Код
Авторство
О чём код?
namespace MassTransit { using System; using System.Collections.Generic; using Configuration; using Transports.Components; public static class KillSwitchConfigurationExtensions { /// <summary> /// A Kill Switch monitors a receive endpoint and automatically stops and restarts the endpoint in the presence of consumer faults. The options /// can be configured to adjust the trip threshold, restart timeout, and exceptions that are observed by the kill switch. When configured on the bus, /// a kill switch is installed on every receive endpoint. /// </summary> /// <param name="configurator">The bus factory configurator</param> /// <param name="configure">Configure the kill switch options</param> public static void UseKillSwitch(this IBusFactoryConfigurator configurator, Action<KillSwitchOptions> configure = default) { if (configurator == null) throw new ArgumentNullException(nameof(configurator)); var options = new KillSwitchOptions(); configure?.Invoke(options); var observer = new EndpointConfigurationObserver(options); configurator.ConnectEndpointConfigurationObserver(observer); configurator.AddPipeSpecification(new KillSwitchOptionsSpecification(options)); } /// <summary> /// A Kill Switch monitors a receive endpoint and automatically stops and restarts the endpoint in the presence of consumer faults. The options /// can be configured to adjust the trip threshold, restart timeout, and exceptions that are observed by the kill switch. When configured on a /// receive endpoint, a kill switch is installed on that receive endpoint only. /// </summary> /// <param name="configurator">The bus factory configurator</param> /// <param name="configure">Configure the kill switch options</param> public static void UseKillSwitch(this IReceiveEndpointConfigurator configurator, Action<KillSwitchOptions> configure = default) { if (configurator == null) throw new ArgumentNullException(nameof(configurator)); var options = new KillSwitchOptions(); configure?.Invoke(options); var killSwitch = new KillSwitch(options); configurator.ConnectReceiveEndpointObserver(killSwitch); configurator.ConnectActivityObserver(killSwitch); configurator.AddPipeSpecification(new KillSwitchOptionsSpecification(options)); } class EndpointConfigurationObserver : IEndpointConfigurationObserver { readonly KillSwitchOptions _options; public EndpointConfigurationObserver(KillSwitchOptions options) { _options = options; } public void EndpointConfigured<T>(T configurator) where T : IReceiveEndpointConfigurator { var killSwitch = new KillSwitch(_options); configurator.ConnectReceiveEndpointObserver(killSwitch); configurator.ConnectActivityObserver(killSwitch); } } class KillSwitchOptionsSpecification : IPipeSpecification<ConsumeContext> { readonly KillSwitchOptions _options; public KillSwitchOptionsSpecification(KillSwitchOptions options) { _options = options; } public void Apply(IPipeBuilder<ConsumeContext> builder) { } public IEnumerable<ValidationResult> Validate() { return _options.Validate(); } } } }