code/modules/power/monitor.dm
256 строк
9 KB
jwhitak
Runtime fixes 20260615 (#39400)
24 июн 2026, 14:17
Не верифицирован
24 июн 2026, 14:17
2c51535
Код
Авторство
О чём код?
/* * For reference, this is the JSON being produced by ui_data() that will be sent to PowerMonitor.js: * * { * "engineer_access": Boolean. Whether the user has minor engineering access (same access as APCs). Enables priority buttons. * "attached": Boolean. Whether the console is attached to a grid * * "history": { * "supply": Float List. Contains previous measurements of power available to the grid. * "demand": Float List. Contains previous measurements of power requested by the grid. * }, * "supply": String. Last measured supply, preformatted. eg: 1234.5 becomes "1.23 kW" * "demand": String. Last measured demand, preformatted. * * "areas": Map. Key is the area's \ref, value is area stats and machine list. May contain a * fake "\ref[null]" area named "Other" grouping any machines whose area can't be determined * Value is as follows: * { * "name": String. Area name * * "demand": Float. Sum of machine and APC demand in this area. * "f_demand": String. Preformatted version of "demand". eg: 1234.5 becomes "1.23 kW" * * "charge": Float, 0 to 100. Area's APC percent charge * "charging": Integer, -1 to 1. Whether the area's APC is currently charging (1), unchanged (0) or discharging (-1) * * "eqp": Integer, 0 to 3. Whether the APC's equipment channel is off (0), auto-off (1), on (2) or auto-on (3) * "lgt": Integer, 0 to 3. Whether the APC's light channel is off (0), auto-off (1), on (2) or auto-on (3) * "env": Integer, 0 to 3. Whether the APC's enviroment channel is off (0), auto-off (1), on (2) or auto-on (3) * * "machines": Map. Key is the machine's identifier, usually derived from "\ref[src]". May identify separate aspects * of the same object, eg: powering things in an APC's area (identified as "\ref[src]") vs recharging said * APC's battery (identified as "\ref[src]_b"). * Value is as follows: * { * "ref": String, "\ref[src]". A reference, for use in Topic() calls, to the object managing this machine's priority * "name": String. Machine name. * * "priority": Integer, ranges 1 to 11. Machine priority. Keep in mind priority level 1 is reserved for * rogue power consumers (eg: syndicate tech, pulse demons) and not meant to be recognized. * * "demand": Float. Power being requested by this machine * "f_demand": String. Preformatted version of "demand". eg: 1234.5 becomes "1.23 kW" * * "isbattery": Boolean. Whether this machine has an internal battery, eg: an SMES, an APC's battery * "charge": Float, 0 to 100. Machine percent charge * "charging": Integer, -1 to 1. Whether the machine's battery is charging (1), unchanged (0) or discharging (-1) * } * } * } */ /obj/machinery/computer/powermonitor name = "power monitor" desc = "It monitors power levels across the station." icon = 'icons/obj/computer.dmi' icon_state = "power" circuit = /obj/item/weapon/circuitboard/powermonitor use_auto_lights = 1 light_range_on = 2 light_power_on = 1 light_color = LIGHT_COLOR_YELLOW use_power = MACHINE_POWER_USE_IDLE idle_power_usage = 300 active_power_usage = 300 //var/datum/powernet/connected_powernet var/datum/power_connection/power_connection = null var/list/history = list() var/record_size = 60 var/record_interval = 50 var/next_record = 0 /obj/machinery/computer/powermonitor/New() ..() power_connection = new(src) /obj/machinery/computer/powermonitor/Destroy() if(power_connection) QDEL_NULL(power_connection) . = ..() /obj/machinery/computer/powermonitor/initialize() ..() search() history["supply"] = list() history["demand"] = list() /obj/machinery/computer/powermonitor/proc/search() var/obj/machinery/power/apc/areaapc = get_area(src).areaapc if(areaapc) var/turf/T = get_turf(areaapc) var/obj/structure/cable/C = T.get_cable_node() power_connection.connect(C) power_connection.connect() /obj/machinery/computer/powermonitor/attack_hand(mob/user) . = ..() if(.) return tgui_interact(user) /obj/machinery/computer/powermonitor/tgui_interact(mob/user, datum/tgui/ui) ui = SStgui.try_update_ui(user, src, ui) if(!ui) ui = new(user, src, "PowerMonitor") ui.open() ui.set_autoupdate(TRUE) /obj/machinery/computer/powermonitor/ui_data(mob/user) var/list/data = list() var/datum/powernet/connected_powernet = power_connection.get_powernet() data["engineer_access"] = (access_engine_minor in user.GetAccess()) // Engineer access allows players to modify priorities data["attached"] = connected_powernet ? TRUE : FALSE data["history"] = history if(!connected_powernet) return data data["supply"] = format_watts(connected_powernet.avail) data["demand"] = format_watts(connected_powernet.viewload) data["areas"] = list() var/list/obj/machinery/power/machines = list() for(var/obj/machinery/power/machine in connected_powernet.nodes) if (istype(machine, /obj/machinery/power/terminal)) var/obj/machinery/power/terminal/T = machine machine = T.master if (istype(machine, /obj/machinery/power/apc)) var/obj/machinery/power/apc/apc = machine var/list/apc_status = apc.get_monitor_status() if (apc_status) //broken APCs and APCs being dismantled will return null, don't forget to check for those apc_status["\ref[apc]"]["f_demand"] = format_watts(apc_status["\ref[apc]"]["demand"]) data["areas"]["\ref[get_area(apc)]"] = list( "name" = get_area(apc).name, "demand" = apc_status["\ref[apc]"]["demand"], "charging" = MONITOR_STATUS_BATTERY_STEADY, "charge" = 0, "eqp" = apc.equipment, "lgt" = apc.lighting, "env" = apc.environ, "machines" = apc_status ) if (apc_status["\ref[apc]_b"]) apc_status["\ref[apc]_b"]["f_demand"] = format_watts(apc_status["\ref[apc]_b"]["demand"]) data["areas"]["\ref[get_area(apc)]"]["demand"] += apc_status["\ref[apc]_b"]["demand"] data["areas"]["\ref[get_area(apc)]"]["charging"] = apc_status["\ref[apc]_b"]["charging"] data["areas"]["\ref[get_area(apc)]"]["charge"] = apc_status["\ref[apc]_b"]["charge"] else if (machine && !(machine in machines)) //Some machines (eg: SMES) could have an input terminal and output wire knot on machines += machine // the same grid, counting them twice. This prevents that var/unknown_areas = FALSE var/list/unknown_area = list( "name" = "Other", "demand" = 0, "machines" = list() ) var/list/areas = data["areas"] for (var/obj/machinery/power/machine in machines) var/list/status_list = machine.get_monitor_status() if (status_list) var/list/apcarea = areas["\ref[get_area(machine)]"] if (!apcarea) unknown_areas = TRUE apcarea = unknown_area for (var/key in status_list) status_list[key]["f_demand"] = format_watts(status_list[key]["demand"]) apcarea["machines"][key] = status_list[key] apcarea["demand"] += status_list[key]["demand"] for (var/datum/power_connection/component in connected_powernet.components) var/list/status_list = component.get_monitor_status() if (status_list) var/list/apcarea = areas["\ref[get_area(component.parent)]"] if (!apcarea) unknown_areas = TRUE apcarea = unknown_area for (var/key in status_list) status_list[key]["f_demand"] = format_watts(status_list[key]["demand"]) apcarea["machines"][key] = status_list[key] apcarea["demand"] += status_list[key]["demand"] if (unknown_areas) data["areas"]["\ref[null]"] = unknown_area for (var/apcarea in areas) areas[apcarea]["f_demand"] = format_watts(areas[apcarea]["demand"]) return data /obj/machinery/computer/powermonitor/proc/record() if(world.time >= next_record) next_record = world.time + record_interval var/list/supply = history["supply"] if(!supply) history["supply"] = list() supply = history["supply"] var/list/demand = history["demand"] if(!demand) history["demand"] = list() demand = history["demand"] var/datum/powernet/connected_powernet = power_connection.get_powernet() if(connected_powernet) supply += connected_powernet.avail if(supply.len > record_size) supply.Cut(1, 2) demand += connected_powernet.viewload if(demand.len > record_size) demand.Cut(1, 2) /obj/machinery/computer/powermonitor/power_change() search() ..() /obj/machinery/computer/powermonitor/process() record() /obj/machinery/computer/powermonitor/ui_act(action, params, datum/tgui/ui) . = ..() if(.) return if(action == "priority") var/value = params["value"] var/id = params["id"] // Ensure the user has engineer access and isn't setting bogus priority values if (!(access_engine_minor in ui.user.GetAccess()) || value < POWER_PRIORITY_CRITICAL || value > POWER_PRIORITY_MINIMAL) return var/datum/D = locate(params["ref"]) if (istype(D, /obj/machinery/power)) var/obj/machinery/power/machine = D machine.change_priority(value, id) else if (istype(D, /datum/power_connection)) var/datum/power_connection/machine = D machine.change_priority(value, id) return TRUE