/
githubmirror
/
nvme-cli
Обзор
Документация
Войти
/
githubmirror
/
nvme-cli
Код
Запросы
0
Пакеты
0
Релизы
0
Аналитика
Безопасность
master
Documentation/nvme-write-zeroes.1
222 строки
6 KB
Daniel Wagner
doc: Regenerate all docs for v3.0-b.5
07 авг 2026, 18:03
07 авг 2026, 18:03
8c9e089
Код
Авторство
О чём код?
'\" t .\" Title: nvme-write-zeroes .\" Author: [FIXME: author] [see http://www.docbook.org/tdg5/en/html/author] .\" Generator: DocBook XSL Stylesheets vsnapshot <http://docbook.sf.net/> .\" Date: 08/07/2026 .\" Manual: NVMe Manual .\" Source: NVMe .\" Language: English .\" .TH "NVME\-WRITE\-ZEROES" "1" "08/07/2026" "NVMe" "NVMe Manual" .\" ----------------------------------------------------------------- .\" * Define some portability stuff .\" ----------------------------------------------------------------- .\" ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ .\" http://bugs.debian.org/507673 .\" http://lists.gnu.org/archive/html/groff/2009-02/msg00013.html .\" ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ .ie \n(.g .ds Aq \(aq .el .ds Aq ' .\" ----------------------------------------------------------------- .\" * set default formatting .\" ----------------------------------------------------------------- .\" disable hyphenation .nh .\" disable justification (adjust text to left margin only) .ad l .\" ----------------------------------------------------------------- .\" * MAIN CONTENT STARTS HERE * .\" ----------------------------------------------------------------- .SH "NAME" nvme-write-zeroes \- Send an NVMe write zeroes command, return results .SH "SYNOPSIS" .sp .nf \fInvme\fR [<global\-options>] \fIwrite\-zeroes\fR <device> [\-\-start\-block=<slba> | \-s <slba>] [\-\-block\-count=<nlb> | \-c <nlb>] [\-\-ref\-tag=<reftag> | \-r <reftag>] [\-\-prinfo=<prinfo> | \-p <prinfo>] [\-\-app\-tag\-mask=<appmask> | \-m <appmask>] [\-\-app\-tag=<apptag> | \-a <apptag>] [\-\-deac | \-d] [\-\-limited\-retry | \-l] [\-\-force\-unit\-access | \-f] [\-\-namespace\-id=<nsid> | \-n <nsid>] [\-\-storage\-tag<storage\-tag> | \-S <storage\-tag>] [\-\-storage\-tag\-check<storage\-tag\-check> | \-C <storage\-tag\-check>] [\-\-dir\-type=<dtype> | \-T <dtype>] [\-\-dir\-spec=<dspec> | \-D <dspec>] [\-\-namespace\-zeroes | \-Z] .fi .SH "DESCRIPTION" .sp The Write Zeroes command is used to set a range of logical blocks to 0\&. .SH "OPTIONS" .PP \-s <slba>, \-\-start\-block=<slba> .RS 4 Start block\&. .RE .PP \-c <nlb>, \-\-block\-count=<nlb> .RS 4 Number of logical blocks to write zeroes\&. .RE .PP \-p <prinfo>, \-\-prinfo=<prinfo> .RS 4 Protection Information field definition\&. .TS allbox tab(:); lt lt lt lt lt lt lt lt lt lt lt lt. T{ Bit T}:T{ Description T} T{ 3 T}:T{ PRACT: Protection Information Action\&. When set to 1, PI is stripped/inserted on read/write when the block format\(cqs metadata size is 8\&. When set to 0, metadata is passes\&. T} T{ 2:0 T}:T{ PRCHK: Protection Information Check: T} T{ 2 T}:T{ Set to 1 enables checking the guard tag T} T{ 1 T}:T{ Set to 1 enables checking the application tag T} T{ 0 T}:T{ Set to 1 enables checking the reference tag T} .TE .sp 1 .RE .PP \-r <reftag>, \-\-ref\-tag=<reftag> .RS 4 Optional reftag when used with protection information\&. .RE .PP \-m <appmask>, \-\-app\-tag\-mask=<appmask> .RS 4 Optional application tag mask when used with protection information\&. .RE .PP \-a <apptag>, \-\-app\-tag=<apptag> .RS 4 Optional application tag when used with protection information\&. .RE .PP \-l, \-\-limited\-retry .RS 4 Sets the limited retry flag\&. .RE .PP \-d, \-\-deac .RS 4 Sets the DEAC bit, requesting controller deallocate the logical blocks\&. .RE .PP \-f, \-\-force\-unit\-access .RS 4 Set the force\-unit access flag\&. .RE .PP \-n <nsid>, \-\-namespace\-id=<nsid> .RS 4 Namespace ID use in the command\&. .RE .PP \-S <storage\-tag>, \-\-storage\-tag=<storage\-tag> .RS 4 Variable Sized Logical Block Storage Tag(LBST)\&. .RE .PP \-C <storage\-tag\-check>, \-\-storage\-tag\-check=<storage\-tag\-check> .RS 4 This bit specifies the Storage Tag field shall be checked as part of end\-to\-end data protection processing\&. .RE .PP \-T <dtype>, \-\-dir\-type=<dtype> .RS 4 Directive type .RE .PP \-D <dspec>, \-\-dir\-spec=<dspec> .RS 4 Directive specific .RE .PP \-Z, \-\-namespace\-zeroes .RS 4 If set, then the controller clear all logical blocks to zero in the entire namespace\&. .RE .SH "GLOBAL OPTIONS" .sp The following options are defined at the top\-level nvme command and are available to this subcommand: .PP \-\-dry\-run .RS 4 Print the command that would be executed, but do not actually execute it\&. .RE .PP \-\-no\-ioctl\-probing .RS 4 Disable probing for 64\-bit IOCTL support\&. .RE .PP \-\-no\-retries .RS 4 Disable retry logic on transient errors\&. .RE .PP \-o <fmt>, \-\-output\-format=<fmt> .RS 4 Set the reporting format to \fInormal\fR, \fItabular, \*(Aqjson\fR, or \fIbinary\fR\&. Only one output format may be used at a time\&. .RE .PP \-\-output\-format\-version=<version> .RS 4 Select the output format version\&. Version \fI1\fR uses the original field naming, while version \fI2\fR (default) provides more consistent and script\-friendly field names\&. .RE .PP \-\-timeout=<ms> .RS 4 Set the timeout for the command in milliseconds\&. .RE .PP \-v, \-\-verbose .RS 4 Increase the level of detail in the output\&. May be specified multiple times to further increase verbosity\&. .RE .sp These options can also be set as machine\-wide defaults in nvme\-cli\&.conf(5)\&. A command\-line flag always overrides the file\&. .SH "EXAMPLES" .sp No examples yet\&. .SH "NVME" .sp Part of the nvme\-user suite