/
githubmirror
/
cmssw
Обзор
Документация
Войти
/
githubmirror
/
cmssw
Код
Запросы
0
Пакеты
0
Релизы
0
Аналитика
Безопасность
master
DQM/DTMonitorModule/python/dt_dqm_sourceclient_common_cff.py
129 строк
5 KB
Javier
Removed DT ML test from client
13 фев 2026, 18:28
13 фев 2026, 18:28
fa2aaea
Код
Авторство
О чём код?
import FWCore.ParameterSet.Config as cms # filter on trigger type calibrationEventsFilter = cms.EDFilter("HLTTriggerTypeFilter", # 1=Physics, 2=Calibration, 3=Random, 4=Technical SelectedTriggerType = cms.int32(2) ) # filter on trigger type physicsEventsFilter = cms.EDFilter("HLTTriggerTypeFilter", # 1=Physics, 2=Calibration, 3=Random, 4=Technical SelectedTriggerType = cms.int32(1) ) # GT unpacker import EventFilter.L1GlobalTriggerRawToDigi.l1GtUnpack_cfi gtDigis = EventFilter.L1GlobalTriggerRawToDigi.l1GtUnpack_cfi.l1GtUnpack.clone( DaqGtInputTag = 'rawDataCollector' ) from EventFilter.L1TRawToDigi.gtStage2Digis_cfi import gtStage2Digis gtStage2Digis.InputLabel = 'rawDataCollector' # Scalers info from EventFilter.ScalersRawToDigi.ScalersRawToDigi_cfi import * scalersRawToDigi.scalersInputTag = 'rawDataCollector' # DT digitization and reconstruction # Switched to TwinMux from EventFilter.L1TXRawToDigi.twinMuxStage2Digis_cfi import * twinMuxStage2Digis.DTTM7_FED_Source = 'rawDataCollector' #dtunpacker.readOutParameters.performDataIntegrityMonitor = True #dtunpacker.readOutParameters.rosParameters.performDataIntegrityMonitor = True #dtunpacker.readOutParameters.debug = False #dtunpacker.readOutParameters.rosParameters.debug = False #dtunpacker.inputLabel = 'rawDataCollector' import EventFilter.DTRawToDigi.dturosunpacker_cfi dtunpacker = EventFilter.DTRawToDigi.dturosunpacker_cfi.dturosunpacker.clone() from RecoLocalMuon.Configuration.RecoLocalMuon_cff import * dt1DRecHits.dtDigiLabel = 'dtunpacker' from Configuration.StandardSequences.FrontierConditions_GlobalTag_cff import * # Data integrity from DQM.DTMonitorModule.dtDataIntegrityTask_cfi import * from DQM.DTMonitorClient.dtDataIntegrityTest_cfi import * from DQM.DTMonitorClient.dtBlockedROChannelsTest_cfi import * dtDataIntegrityTask.processingMode = 'Online' dtDataIntegrityTask.dtFEDlabel = 'dtunpacker' blockedROChannelTest.checkUros = True # Digi task from DQM.DTMonitorModule.dtDigiTask_cfi import * from DQM.DTMonitorClient.dtOccupancyTest_cfi import * dtDigiMonitor.readDB = False dtDigiMonitor.filterSyncNoise = True dtDigiMonitor.lookForSyncNoise = True # Local Trigger task from DQM.DTMonitorModule.dtTriggerBaseTask_cfi import * from DQM.DTMonitorModule.dtTriggerLutTask_cfi import * from DQM.DTMonitorClient.dtLocalTriggerTest_cfi import * from DQM.DTMonitorClient.dtTriggerLutTest_cfi import * triggerTest.hwSources = ['TM'] # scaler task from DQM.DTMonitorModule.dtScalerInfoTask_cfi import * # segment reco task from DQM.DTMonitorModule.dtSegmentTask_cfi import * from DQM.DTMonitorClient.dtSegmentAnalysisTest_cfi import * # resolution task from DQM.DTMonitorModule.dtResolutionTask_cfi import * # noise task from DQM.DTMonitorModule.dtNoiseTask_cfi import * from DQM.DTMonitorClient.dtNoiseAnalysis_cfi import * dtNoiseAnalysisMonitor.doSynchNoise = True # report summary from DQM.DTMonitorClient.dtSummaryClients_cfi import * from DQMServices.Core.DQMQualityTester import DQMQualityTester dtqTester = DQMQualityTester( #reportThreshold = cms.untracked.string('red'), prescaleFactor = cms.untracked.int32(1), qtList = cms.untracked.FileInPath('DQM/DTMonitorClient/test/QualityTests.xml'), getQualityTestsFromFile = cms.untracked.bool(True) ) # test pulse monitoring from DQM.DTMonitorModule.dtDigiTask_TP_cfi import * from DQM.DTMonitorClient.dtOccupancyTest_TP_cfi import * # New time window for TPs dtTPmonitor.defaultTtrig = 750 dtTPmonitor.defaultTmax = 200 dtTPmonitor.inTimeHitsLowerBound = 0 dtTPmonitor.inTimeHitsUpperBound = 0 # Local Trigger task for test pulses from DQM.DTMonitorModule.dtTriggerTask_TP_cfi import * from DQM.DTMonitorClient.dtLocalTriggerTest_TP_cfi import * dtTPTriggerTest.hwSources = ['TM'] unpackers = cms.Sequence(dtunpacker + twinMuxStage2Digis + scalersRawToDigi) reco = cms.Sequence(dt1DRecHits + dt4DSegments) # sequence of DQM tasks to be run on physics events only dtDQMTask = cms.Sequence(dtDataIntegrityTask + dtDigiMonitor + dtSegmentAnalysisMonitor + dtTriggerBaseMonitor + dtTriggerLutMonitor + dtNoiseMonitor + dtResolutionAnalysisMonitor) # DQM clients to be run on physics event only dtDQMTest = cms.Sequence(dataIntegrityTest + blockedROChannelTest + triggerLutTest + triggerTest + dtOccupancyTest + segmentTest + dtNoiseAnalysisMonitor + dtSummaryClients + dtqTester) # DQM tasks and clients to be run on calibration events only dtDQMCalib = cms.Sequence(dtTPmonitor + dtTPTriggerMonitor + dtTPmonitorTest + dtTPTriggerTest) # sequence to be run on physics events (includes filters, reco and DQM) dtDQMPhysSequence = cms.Sequence(dtScalerInfoMonitor + gtDigis + reco + dtDQMTask + dtDQMTest) from Configuration.Eras.Modifier_stage2L1Trigger_cff import stage2L1Trigger dtDQMPhysSequenceStage2 = cms.Sequence(dtScalerInfoMonitor + gtStage2Digis + reco + dtDQMTask + dtDQMTest) stage2L1Trigger.toReplaceWith(dtDQMPhysSequence,dtDQMPhysSequenceStage2)