/
anve_studio
/
pdf2html-mcp
Обзор
Документация
Войти
/
anve_studio
/
pdf2html-mcp
Код
Запросы
0
Задачи
Вики
Пакеты
0
Релизы
0
CI/CD
Аналитика
Безопасность
master
sample/example_01.html
14 строк
6 KB
Andrey
добавил настройку таймаута
06 авг 2026, 16:22
06 авг 2026, 16:22
2a7e2cb
Код
Авторство
О чём код?
<!DOCTYPE html> <html> <head> <meta charset="utf-8"/> <title>example_01.pdf</title> <style>table{border-collapse:collapse}td,th{border:1px solid #999;padding:4px;vertical-align:top}</style> </head> <body> <h2>3 Technical faults</h2> <table><tr><td colspan="1" rowspan="1">id number (internal use)</td><td colspan="1" rowspan="1">Description</td><td colspan="1" rowspan="1">Device's response alarm or message</td><td colspan="1" rowspan="1">E></td><td colspan="1" rowspan="1">; Trigger condition</td><td colspan="1" rowspan="1">Cancel condition</td><td colspan="1" rowspan="1">Action required</td><td colspan="1" rowspan="1">Service software page No.</td></tr><tr><td colspan="1" rowspan="1">231001</td><td colspan="1" rowspan="1">Pressure Controller Pressure Low</td><td colspan="1" rowspan="1">Disconnection on Ventilator side</td><td colspan="1" rowspan="1">H</td><td colspan="1" rowspan="1">PventControl < (Set pressure -2mbar) for more than 5s</td><td colspan="1" rowspan="1">PventControl ≥ (Set pressure - 2mbàr)</td><td colspan="1" rowspan="1">Check for leaks Check ambient valve [C2]Check Pvent_Control</td><td colspan="1" rowspan="1">2108 2204 2201</td></tr><tr><td colspan="1" rowspan="1">231002</td><td colspan="1" rowspan="1">Pressure Controller Pressure High</td><td colspan="1" rowspan="1">Technical Event 231002</td><td colspan="1" rowspan="1">H</td><td colspan="1" rowspan="1">[C1] PventControl or Paw >PSafetyLimit AND PventControl and Paw after 1s not ≤ (PSafetyLimit – 10mbar)[C2] PventControl >PSafetyLimit AND PventControl after 1s not ≤(PSafetyLimit – 10mbar)</td><td colspan="1" rowspan="1">PventControl ≤(PSafetyLimit-10mbar)</td><td colspan="1" rowspan="1">Check Pvent_Control Check Paw [C1]Perform pressure calibration Perform flow sensor calibration [C1]Check inspiratory valve<br/>- Perform inspiratory valve calibration</td><td colspan="1" rowspan="1">2201 2341 2341 2347 2107 2342</td></tr><tr><td colspan="1" rowspan="1">231003</td><td colspan="1" rowspan="1">Flow Controller Flow Low</td><td colspan="1" rowspan="1">Technical Event 231003</td><td colspan="1" rowspan="1">H</td><td colspan="1" rowspan="1">Qvent < (Set flow - 200ml/s) for more than 5s, where by Set flow= Qvent Set flow + Set flow from the Baseflow regulator</td><td colspan="1" rowspan="1">Qvent ≥ (Set flow -200ml/s)</td><td colspan="1" rowspan="1">Inspiration outlet obstructed Check Qvent sensor Check Inspiratory valve [C2]</td><td colspan="1" rowspan="1">2202 2107</td></tr><tr><td colspan="1" rowspan="1">231004</td><td colspan="1" rowspan="1">Flow Controller Flow High</td><td colspan="1" rowspan="1">Technical Event 231004</td><td colspan="1" rowspan="1">H</td><td colspan="1" rowspan="1">Qvent > (Set flow + 200ml/s) for more than 5s, where by Set flow= Qvent Set flow + Set flow from the Baseflow regulator</td><td colspan="1" rowspan="1">Qvent ≤ (Set flow +200ml/s)</td><td colspan="1" rowspan="1">Check Qvent sensor Check Inspiratory valve [C2]</td><td colspan="1" rowspan="1">2202 2107</td></tr><tr><td colspan="1" rowspan="1">231005</td><td colspan="1" rowspan="1">Inspiration Valve Leak</td><td colspan="1" rowspan="1">Technical Event 231005</td><td colspan="1" rowspan="1">H</td><td colspan="1" rowspan="1">[C2] Qvent > 2l/min when Set flow = 0 for more than 250ms</td><td colspan="1" rowspan="1">Qvent = 0 when Set flow = 0</td><td colspan="1" rowspan="1">Check Inspiratory valve [C2]Check Qvent sensor</td><td colspan="1" rowspan="1">2107 2202</td></tr><tr><td colspan="1" rowspan="1">231006</td><td colspan="1" rowspan="1">O2 Controller Flow Low</td><td colspan="1" rowspan="1">Oxygen supply failed</td><td colspan="1" rowspan="1">H</td><td colspan="1" rowspan="1">QO2 < (Set flow - 20%) for more than 250ms AND Set flow ≥1ml/s AND Set flow < 100l/min</td><td colspan="1" rowspan="1">QO2 ≥ (Set flow -20%) for more than10ms AND Set flow ≥10ml/s</td><td colspan="1" rowspan="1">Check HPO Supply if in specs (2.8 to 6bar , Medical Oxygen)<br/>- If HPO is available check O2 Mixer</td><td colspan="1" rowspan="1">2112</td></tr></table> <table><tr><td colspan="1" rowspan="1">Component Tests</td><td colspan="1" rowspan="1">Symptom</td><td colspan="1" rowspan="1">Required action</td></tr><tr><td colspan="1" rowspan="2"></td><td colspan="1" rowspan="1">Test ends with Status "NOT OK"</td><td colspan="1" rowspan="1">Pressure test: Check Ambient valve [C2](Tests/Calib > Comp test > Pneumatics 2> Ambi valve , Page No 2106)Check Pvent_control and calibrate if necessary (Adj/Calib > Calibration> Pressure,Page No 2341)Calibrate expiratory valve Check expiratory valve membrane and replace if necessary<br/>- Replace expiratory valve cover<br/>- Check for internal leaks<br/>- Replace expiratory valve</td></tr><tr><td colspan="1" rowspan="1">Test ends with Status “NOT OK"</td><td colspan="1" rowspan="1">Leakage test: [C1]<br/>- Check for internal leaks<br/>- Check Ambient valve [C2](Tests/Calib > Comp test > Pneumatics 2> Ambi valve , Page No 2106)<br/>- Check expiratory valve membrane and replace if necessary<br/>- Check Qvent (Tests/Calib > System test > Flow , Page No 2202)</td></tr><tr><td colspan="1" rowspan="3">Pneumatics 1>Insp. Valve(Page No 2107) [C2]</td><td colspan="1" rowspan="1">Test ends with NOT OK</td><td colspan="1" rowspan="1">Leakage:- Check for internal leaks<br/>- Check Qvent (Tests/Calib > System test > Flow , Page No 2202)</td></tr><tr><td colspan="1" rowspan="1">External measured flow does not correspond to Qvent</td><td colspan="1" rowspan="1">Flow Control:- Check for internal leaks Check ambient valve (Tests/Calib > Comp test > Pneumatics 2> Ambi valve, Page No 2112)Calibrate inspiratory valve (Adj/Calib > Calibration> Insp. Valve, Page No 2342)<br/>- Check Qvent (Tests/Calib > System test > Flow, Page No 2202)<br/>- Check cable of inspiratory valve if connected properly</td></tr><tr><td colspan="1" rowspan="1">Test ends with NOT OK</td><td colspan="1" rowspan="1">Pressure:- Check for internal leaks Check ambient valve (Tests/Calib > Comp test > Pneumatics 2> Ambi valve, Page No 2112)<br/>- Perform the calibration of the inspiratory valve (Adj/Calib > Calibration> Insp. Valve,Page No 2342)Check Qvent (Tests/Calib > System test > Flow, Page No 2202)<br/>- Check Pvent_monitor (Adj/Calib > Calibration> Pressure ,Page No 2341)</td></tr></table> </body> </html>